Field
of Application
Pyroplex 30 minute
glazing systems have been specifically designed for use in glazed
apertures in fire doors in the following
applications:
• Glazed apertures in fire resisting timber doors and steel
doors.
Product
Features
• Supplied on continuous reels for dispensing applications,
ease of storage and to reduce wastage in cut-offs. Supplied with a high performance self-adhesive backing for ease of application and installation.
• Pyroplex intumescent material is totally unaffected
by water, robust,‘non-flaking’ and difficult to
tear.
Product
Data
Part
Number |
For Use With
Insulating Glass |
For Use With
Non-Insulating Glass |
| 30049 |
Yes |
Yes |
| 30054 |
Yes |
No |
| 8193 |
Yes |
Yes |
Product Testing;
Pyroplex 30 minute glazing systems have been tested to the
requirements of CERTIFIRE TS25 and other international standards,
including British Standards BS476: Part 22:1987, clause 7 & 8.
| Test Reports & International Standards |
| CERTIFIRE
CF346 & CF348 |
| Mid-East
Listing Scheme ME0042 & ME0043 |
| Bodycote Warringtonfire
136934, 136935, 137714, 139878, 165278 |
|
|
Installation Instructions
All doors must be lined with a 6mm hardwood liner around the perimeter
of the aperture. Failure to line the aperture will invalidate the
CERTIFIRE Approval.
1. Unwind the glazing system from the coil. Remove the release liner
from the product. Fit the product to the bead.
2. Mitre cut the bead (with glazing system installed) to fit the
aperture. Install one complete side of the beading system using M5 x 50
stainless steel screws at 150mm centres.
3. Cut glass to fit aperture with a tolerance of +/-2mm and install. Repeat steps for opposite side
of the door.
|