Test Standard
BS 476: Part 20:22 – Fire
BS EN 1634-1 – Fire
BS EN 1634-3 – Smoke
BS 476: Part 31-1 – Smoke
BS EN ISO 10140-2 – Acoustic
Application: Fire resisting timber doorset
Fire Resistance Period: 30 to 60 minutes
Insulation/integrity: Integrity and insulation
Test Standard: BS 476: Part 20:22, BS EN1634-1 and BS EN ISO 10140-2
Approval Type: Certifire CF822
Pyroplex® Flipper range provides fire, smoke and acoustic seals for timber door edges and frames. The flippers are thermally fused to the box section to ensure that under normal conditions of use they will not delaminate. This new technology ensures improved performance and also appearance of the seal. The Integral Flipper range adds added security with an integral flipper that will remain uninterrupted when used with ironmongery.
Pyroplex® Flipper range provides fire, smoke and acoustic seals, which are supplied in 2.1m lengths as standard and are quick and easy to fit with no special tools required.
BS 476: Part 20:22 – Fire
BS EN 1634-1 – Fire
BS EN 1634-3 – Smoke
BS 476: Part 31-1 – Smoke
BS EN ISO 10140-2 – Acoustic
Certifire TS35 and TS21. Certificate CF822
Pyroplex® Flipper range of Rigid Box Seals have been specifically designed for use in the following applications:
Part no. | Dimensions | 30min fire resistance | 60min fire resistance | Smoke performance | Acoustic performance |
---|---|---|---|---|---|
30160 | 10×4 | ✓ | — | ✓ | ✓ |
30165 | 15×4 | ✓ | — | ✓ | ✓ |
30166 | 20×4 | — | ✓ | ✓ | ✓ |
1. Select the appropriate seal using the door test evidence, which will identify the size of intumescent seal required.
2. Route a groove suitable for the size of intumescent seal.
3. The intumescent seal can be interrupted to allow for ironmongery, whilst still maintaining an integral flipper.
4. Remove the release liner from the product and push fit into the routed groove.
5. To achieve excellent adhesion, seals must be applied to clean, dry surfaces at temperatures between +5°C and +40°C.
Pyroplex® Flipper range provides fire, smoke and acoustic seals, which have been tested to BS 476: Part 20:22, BS EN 1634-3 and BS EN ISO 10140-2. The Flipper range is compliant with the requirements given in Certifire TS35 and TS21. Certifire Certificate No. CF822.
Providing the product is installed in accordance with the requirements of the guidance document the product is guaranteed for a period of 10 years. All Pyroplex® products are identified with a unique reference number for traceability purposes.